Sentry meters, to detect water leaks in the network
Focus
Focus
Category Facet
Custom Facet
Search Results
-
Document on-date Nov 24, 2017 4:12 PM
DICHIARAZIONE AMBIENTALE ANNO 2017 COMPLESSO IMPIANTISTICO DI VIA CARUSO 150 MODENA (MO) Rev. 0 del 14/06/2017 1 PREMESSA Il presente documento costituisce...
-
Document on-date Nov 24, 2017 4:13 PM
DICHIARAZIONE AMBIENTALE ANNO 2017 COMPLESSO IMPIANTISTICO Via del Frullo 3/F Granarolo dell’Emilia (BO) Rev. 0 del 16/06/2017 1 PREMESSA Il presente documento...
-
Document on-date Nov 24, 2017 4:13 PM
DICHIARAZIONE AMBIENTALE ANNO 2017 COMPLESSO IMPIANTISTICO DI VIA SELICE 12/a Mordano (BO) Rev. 0 del 13/06/2017 1 PREMESSA Il presente documento costituisce...
-
Document on-date Mar 22, 2018 2:11 PM
press release Bologna, 27 March 2018 Hera Group approves results at 31/12/2017 Improvement seen in all operating, financial and sustainability indicators. These results, which exceeded...
-
Document on-date Mar 22, 2018 2:11 PM
Consolidated Financial Statements 2017 TABLE OF CONTENTS INTRODUCTION Letter from the Chairman to Shareholders 1 Governance and control bodies 3 Corporate...
-
Document on-date Jun 6, 2018 12:04 PM
DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO I.T.F.I. Via Shakespeare 29, Bologna (BO) Rev. 0 del 05/03/2018 ...
-
Document on-date Jun 6, 2018 12:05 PM
DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO Via dell’Energia, Pozzilli (IS) Rev.0 del 09/03/2018 1 PREMESSA Il presente documento...
-
Document on-date Jun 6, 2018 12:05 PM
0 DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO “Centro Ecologico Baiona” di Via Baiona 182 Ravenna (RA) Rev.0 del 10 aprile 2018 1 ...
-
Document on-date Jul 17, 2018 9:55 AM
DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO DI Via Finati 41/43 Ferrara (FE) Rev. 0 del 16/04/2018 1 PREMESSA Il presente documento...
-
Document on-date Jul 17, 2018 9:55 AM
DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO DI VIA CARUSO 150 MODENA (MO) Rev. 0 del 16/05/2018 1 PREMESSA Il presente documento...
-
Document on-date Jul 17, 2018 9:56 AM
001492001492 DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO Via Cavazza 45 Modena (MO) Rev. 0 del 23/04/2018 1 PREMESSA Il presente...
-
Document on-date Jul 26, 2018 12:20 PM
press release Bologna, 30 July 2018 Hera BoD approves 1H2018 results The consolidated half-year report at 30 June confirms growth in operating and financial indicators, in line with the...
-
Document on-date Aug 3, 2018 12:05 PM
001398001398 DICHIARAZIONE AMBIENTALE ANNO 2018 COMPLESSO IMPIANTISTICO Via Grigioni 19-28, Forlì (FC) Rev. 0 del 28/05/2018 1 PREMESSA Il presente...
-
Document on-date Jan 7, 2019 10:29 AM
press release Bologna, 10 January 2019 Hera Group approves Business Plan to 2022 Based on solid forecast for 2018, which significantly exceeded the goal of one billion in Ebitda, this new...
-
Document on-date Mar 25, 2019 9:51 AM
FACT SHEET YEAR 2018 www.gruppohera.it CONTACTS INVESTOR RELATIONS HERA SpA Viale Berti Pichat, 2/4 - 40127 Bologna Tel.: +39 051 28 71 11 Fax: +39...
-
Document on-date Mar 25, 2019 9:51 AM
C o n so lid ated F in an cial S tatem en ts 2018 Consolidated Financial Statements 2018 Hera Group – Consolidated Financial Statements at 31 December 2018, approved by the Hera...
-
Document on-date Apr 8, 2019 2:47 PM
1 Consolidated non-financial reporting drawn up pursuant to articles 3 and 4 of Italian Leg. Decree 254/2016 2 Content Sustainability, Strategy and Shared Value...
-
Document on-date Jun 17, 2019 2:30 PM
D IC H IA R A Z IO N E A M B IE N T A L E 2 0 1 9 COMPLESSO IMPIANTISTICO “TRE MONTI” Via Pediano 47c/52 Imola (BO) Rev. 0 del 07/03/2019 DATI AGGIORNATI AL 31/12/2018 ...
-
Document on-date Jun 17, 2019 2:30 PM
D IC H IA R A Z IO N E A M B IE N T A L E 2 0 1 9 COMPLESSO IMPIANTISTICO Via Tomba 25 Lugo (RA) Rev. 0 del 26/03/2019 DATI AGGIORNATI AL 31/12/2018 ...
-
Document on-date Jun 17, 2019 2:30 PM
D IC H IA R A Z IO N E A M B IE N T A L E 2 0 1 9 COMPLESSO IMPIANTISTICO DI VIA SELICE 12/a Mordano (BO) Rev. 0 del 14/03/2019 DATI AGGIORNATI AL 31/12/2018 ...
Asset Publisher
The pilot project involving the installation of Kamstrup meters was carried out in Conselice, near Ravenna, and yielded excellent results. The tests now continue in Modena, covering a larger area
The Flow IQ® 2200 manufactured by Kamstrup, a well-established European supplier, is a sentry meter that can “listen” to the network thanks to a built-in hydrophone, i.e. a sensor designed to capture sounds and other acoustic signals underwater, which in this case is able to detect the noise associated with any water leaks.
By placing the meters at strategic points in the network, about 50 metres apart, it is possible to create a grid within which continuous monitoring can be carried out.
The meters transmit to a digital platform (called the LeakDetector) the minimum value of noise detected in 24 hours: if this is high, the meters will be highlighted with different alarm levels and analysis of the data will make it possible to identify whether it is indeed a water leak.
If a leak or break code is activated for a meter, the customer will be notified promptly by our technicians.
The meter testing phase started in May 2022 with the installation of more than 900 meters in the municipality of Conselice, where continuous monitoring of the water network began in September 2022 with real-time analysis of the leaks present, thereby allowing targeted intervention for repairs.
It is planned to continue testing over a wider area, starting with Modena, where 1,300 meters are being installed.
The Conselice pilot project: benefits noted
Reliability
The meters are extremely reliable, the leak and break indications that were verified were correct and no false positives were found.
Promptness
We intervened before customers called us: many leaks were repaired the day after they appeared, whereas previously some leaks would only have been detected following issue of a bill with an unusually high consumption figure.
Permanent monitoring
Compared to the installation of standard meters, the main difference is that with Flow IQ® 2200s, a permanent water leak monitoring system is put in place. Kamstrup meters are also smart meters and automatically send data to the portal.
Rapid localisation
If the meters are correctly positioned, field localisation is quick because the area to be investigated is confined.
Integration
The system interfaces seamlessly with other company monitoring tools.
Affordability
By correctly establishing the number of meters required, good network coverage is achieved without an unsustainable increase in costs.
Search Bar
Tag Facet
Search Results
Asset Publisher